Logo

High Frequency UPS

High Frequency UPS systems are vital for maintaining uninterrupted power supply in critical applications. Utilizing advanced technology, they swiftly convert alternating current (AC) to direct current (DC) for storage in batteries, ensuring seamless power delivery during outages.

Their compact design and high efficiency make them ideal for industrial, commercial, and residential settings. With features like intelligent monitoring and integration with renewable energy sources, High Frequency UPS systems offer reliable and sustainable power backup solutions. These systems play a crucial role in safeguarding equipment, ensuring business continuity, and minimizing downtime in various sectors.

Technical Data Specifications MSI Series 1 -10KVA

STANDARD MODEL MSI1101B2 MSI110284 MSI1103B6 MSI1106B16 MSI1110816
LONG-RUN MSI1101L3 MSI1102L6 MSI1103L6 MSI1106L16 MSI1110L16
PHASE Single phase with ground
CAPACITY * 1000 VA / 900 W 2000 VA 1800 W 3000 VA / 2700 W 6000VA/5400W 10000 VA 9000 W
INPUT
Nominal Input Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC
Input Voltage Range 55-150 VAC or 110-300 VAC (Based on load at 50%)
85-140VAC or 160-280VAC (Based on load at 100%)
110-300 VAC (Based on load at 50%)
176-300 VAC (Based on load at 100%)
Frequency Range 46-54 Hz or 56-64 Hz
Power Factor 0.99 @ Nominall Voltage (100% load)
OUTPUT
Output Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC
Frequency (Synchronized Range) 47- 53 Hz or 57 63 Hz 46-54 Hz or 56-64 Hz
Frequency Range (Batt. Mode) 50 Hz + 0.25 Hz or 60Hz 2 0.3 Hz 50 Hz or 60Hz + 0.1 Hz
Current crest Ratio 3:1
Harmonic Distortion ≤ 3 % THD (Linear Load)
≤ 6 % THD (Non-linear Load)
≤ 3 % THD (linear Load)
≤ 5 % THD (Non-linear Load)
Transfer Time AC Model to Battery Mode Zero
Inverter to Bypass 4 ms (Typical) Zero
Waveform (Batt. Mode) Pure Sinewave
EFFICIENCY
AC Mode 88% 89% 90% 92% 93%
Battery Mode 83% 87% 88% 90% 91%
BATTERY
Standard Model Battery Type 12V/9Ah 12V/9Ah 12V/9Ah 12V/9Ah
Numbers 2 4 6 16
Typical Recharge Time 4 hours recover to 90% capacity 9 hours recover to 90% capacity
Charging Current (max.) 1A 1A/2A
Charging Voltage 27.4VDC±1% 54.7 VDC±1% 82.1 VDC±1% 218.4 VDC±1%
Long-run Model** Battery Type Depending on the capacity of external batteries
Numbers 3 6 6 16-20 (Adjustable)
Charging Current (max.) 1A/2A/4A/6A (Adjustable) 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries)
Charging Voltage 41.0VDC±1% 82.1 VDC±1% 82.1 VDC ±1% 273 VDC ±1% (Based on 20pcs batteries)
INDICATORS
LCD Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every
Fault Continuously sounding
PHYSICAL
Standard Model Dimension, x x x x (mm) 282 145 x 220 397x145x220 421 x 190 x 318 369 X 190 688 442 x 190 688
Net Weight (kgs) 9.8 17 26.6 61 66
Dimension, DxWxH (mm) 282 x 145 x 220 397 x 145 X 220 369 X 190 x 318 442 x 190 x 318
Net Weight (kgs) 4.1 6.8 7.4 12 16
ENVIRONMENT
Humidity 20-90 % RH @ 0-40°C (Non-condensing) "0-95% RH @ 0-50°C (non-condensing)" "0.95% RH @ 0-40°C (non-condensing)"
Noise Level Less than 50dB @ 1 Meter Less than 55dB @ 1 Meter Less than 58dB 1 Meter
MANAGEMENT
Smart Optional RS-232/ USB Supports Windows 2000/2003/XP/Vista/2008 Windows 7/8/10, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
  • *1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC.
  • 6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC.
  • **Long-run model is only available for 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA).
  • Product specifications are subject to change without further notice.